background
Xerox® 4030 Cartridge
Reference Information:
OEM PN: 13-R32
OEM Yield: 10,000 (5.5% coverage)
Recommended Tools:
Phillips screwdriver
Instructions:
Figure 1
1. Locate and remove the C clip on the large gear on the right hand side of the
cartridge (Fig. 1).
2. Slide off the gear, remove the small securing pin, and small white hub from the
axle (Fig. 2).
3. Pry out and remove the black retaining hub (Fig. 4) on the left hand side of the
Figure 2
cartridge.
4. Remove the OPC drum. Clean, inspect, and lubricate the drum. Store in a
dark place, replace if necessary.
5. Remove the 4 screws on the top of the cartridge (Fig. 5).
6. Lift the top cover and bracket off of the cartridge (Fig. 6).
Figure 3
7. Use compressed air or a vacuum to clean out residual toner from the hopper.
8. Remove the 2 wiper blade screws. Remove and clean the wiperblade, being
careful not to bend or crease the small mylar strip immediately below it (Fig. 7).
Figure 4
9. Re-assemble the cartridge in reverse order.
Figure 7
Figure 6
© 2001 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis Imaging
Products, Inc. may result in legal action. All registered trademarks are the property of their respective owners.
Oasis Imaging Products, Inc. Technical Support: (888) 627-6555