background
Fuji® XP 5/10
Remanufacturing Instructions
Reference Information:
Remanufacturing
OEM PN: M1960G/A
Time: 35 min.
OEM Yield: 3,000
(5% coverage)
Recommended Tools:
Printer Compatibility
Phillips head screwdriver
APPLE LASERWRITER SELECT 300, 310, 360
Jewelers screwdriver
PANAFAX UF 755
Pliers
STAR MICRONICS LS-5, LS5EX, LS5TT
Glue
XEROX 4010
Utility Knife
Instructions:
Figure 1
1. Push in locking pins (Figs. 1 & 2) with jewelers screwdriver until top cover
springs open.
2. Remove the OPC hub screws (Figs. 1 & 2) and remove hubs.
3. Remove the OPC. Clean, inspect, and replace if necessary. Store in a dark
place.
Figure 2
4. Remove toner cap and doctor blade (2 screws) (Fig. 3). Use compressed air
or a vacuum to clean out the toner hopper. Replace the doctor blade.
5. Remove pins from pin holder (Fig. 4).
6. Remove, clean and inspect the PCR (Fig 4).
7. Vacuum excess waste toner from waste hopper.
8. Clean all contacts.
Figure 3
9. Remove end plate, and lift out mag roller. Clean and inspect the mag roller
sleeve and contacts.
10. Replace mag roller and end plate.
11. Fill hopper with toner and replace cap.
12. Replace PCR and OPC. Screw the gear hubs back in place.
Figure 4
13. Reassemble cartridge, pushing pins back into place to secure
© 2001 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis Imaging