background
Xerox® XD100 Cartridge Remanufacturing Instructions...
1
Xerox® XD100
Remanufacturing Instructions
Reference Information:
Approximate Remanufacturing
OEM PN: 13R551
Time: 20-25 minutes
OEM Yield: 18,000
@ 5% page coverage
Recommended Tools:
Materials Needed:
Phillips-head screwdriver
Soft, lint-free cloths P/N:99CL14
Small, flat-head screwdriver
Oasis OPC P/N: XDDR1105
Drum Unit Disassembly



Oasis Imaging Products, Inc. Technical Support: (888) 627-6555
1. Four locking tabs secure the gear cap to the drum unit
(Fig.1). Squeeze the cap and use a flat head screwdriver to
release the locking tabs. Remove the cap and set aside.
2. The drum axle (Fig. 2) is in a
locked position and is seated flush
to the drum housing. Using needle
nose pliers, rotate the axle counter
clockwise a quarter turn to release
the axle from its locked position.
Remove the axle and carefully
remove the drum.
3.Two screws hold the corona wire housing
in place. Remove the two screws (Fig.3).
Fig. 1
Fig. 2
Fig. 3
background



© 2001 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis
Imaging Products, Inc. may result in legal action. All registered trademarks are the property of their respective owners.
4. Using a small flat head screwdriver, gently pry up (gear side) on
the black plastic screw housing that is attached to the corona wire
housing. Once the housing is released pull the housing up and towards
you to remove it. Clean the corona wire with compressed air.
5. Remove the two screws that hold the
wiper blade in place (Fig.4).
Remove the blade (Fig. 5) and clean with
compressed air.
Clean the waste bin with compressed air.
6. Reassemble the cartridge in reverse order to
insure proper assembly.
Fig. 4
Fig. 5