background
Canon® LX
Remanufacturing Instructions
Reference Information:
Approximate Remanufacturing
OEM PN: 92275A
Time: 20 min.
OEM Yield: 3500 prints (5% image area)
Tools Needed:
Front end cutters
Phillips head screwdriver
Needle nose Pliers
99% Isopropyl Alcohol
Anakenesis® PCR Cleaner
Cotton swabs
Instructions:
Figure 1
1. Separate the wastebin(OPC unit) and toner hopper (2 pins, 1 spring).
2. Remove the OPC drum (2 screws, Fig. 2). NOTE: Move the shutter to the
open position to access the 2 hub screws. Remove the hub. Lift the OPC
drum by the large helical gear. Clean, inspect and lubricate the drum.
Replace if necessary.
3. Remove the primary charge roller (PCR). Apply Anakenisis® PCR cleaner
to a clean, lint-free cloth. Wipe the length of the PCR until all the residue is
removed (Fig. 3). Make sure to clean the black conductive clip that holds the
PCR with a cotton swab saturated with 99% IPA.
4. Remove the wiper blade from the OPC unit and clean with a lint-free cloth
saturated with 99% IPA. (2 screws). Dump the remaining toner from the
Figure 2
waste bin and use compressed air to remove residual toner.
NOTE: Be careful not to crimp or bend the thin mylar strip.
5. Install clean wiperblade and secure with 2 screws.
6. Install
clean
PCR.
7. Install lubricated OPC with axle hub (2 screws).
8. Remove toner hopper plug and empty out remaining toner (Fig 4). Use
compressed air to remove all residual toner.
Figure 3
9. To disassemble the toner hopper: remove the mag roller end plate on the
right side of the cartridge (2 screws). Clean the contact with a cotton swab
saturated with 99% IPA.
10. Gently lift the mag roller from the hopper unit and remove the bushings, mag
roller bearing and the drive gear. Use compressed air to remove toner from the
surface of the mag roller. Clean bushings with compressed air or a cotton swab
saturated with 99% IPA.
11. Remove the toner hopper plug and empty out remaining toner. Use com-
Figure 4
pressed
12. Remove the doctor blade (2 screws). Use a clean, lint-free cloth to clean the
blade. Use compressed air to remove all residual toner.
Oasis Imaging Products, Inc. Technical Support: (888) 627-6555
Canon® LX Remanufacturing Instructions...
1
background
2
13. Install the doctor blade and secure with 2 screws.
14. Install the mag roller (with clean bushings), then replace the gear cover.
15. Fill the hopper unit with toner and install the hopper cap.
16. Attach the OPC unit and toner hopper (replace the pins and re-connect
the springs).
Printer Compatibility Information:
APPLE PERSONAL LASERWRITER:
LS, NT, NTR, SC
BECKS IMPORT INC:
440, 460
BEZIER BP 4040
BROTHER HL
4, 4PS, 4V, 4Ve, 6
CANON LBP-4:
PLUS, III PLUS
4 LITE, 4SX
CANON LBP-LX
CANON P 110
DEC DECLASSER
:
1100, 1150, 1152
DEC LN 07
DIGITAL LASER SYS PLUS
:
121, 141 D, 181
HEWLETT PACKARD LASERJET:
IIP, IIIP PLUS, IIIP, IIIP/MAC
33471 A
LASERMASTER:
LASERMAX 400, MAXWRITER 600
LASERMASTER WINPRINTER:
400, 800, 800, 800/4, 1000/4 AFM
1000/4 KX
NEWGEN SYS. TURBO PS:
300P, 360P, 400P, 660P, 880P
PRINTER WORKS LX-29000
PRINTERS PLUS SCRIPTWRITER 4 PS
QMS PS 410
SANYO SPX:
406, 406PS
SIEMANS HIGHPRINT 7500
SRS IMAGING PERSONAL IMAGER
STAR MICRONICS LASERPRINTER:
4, 4 III, 4 STARSCRIPT
WANG: LDT-4P, LDT-4 III
XANTE CORP ACCEL-A-WRITER 4000
XLI CORP XPERT 1000S
© 2001 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis Imaging
Products, Inc, may result in legal action. All registered trademarks are the property of their respective owners.