Ricoh® 4080/4081 Belt Replacement
Recommended Tools:
Approximate Remanufacturing
Phillips head screwdriver
Time: 15-20 min.
Small flat head screwdriver
Instructions:
1. Remove two screws on corona assembly. The corona grid unit has spring ten-
sion and and be removed by first pushing it to the left and then lifting off
(Fig. 1).
2. Remove four screws on bottom of belt housing (Fig. 2).
a. Lift cover off carefully.
b. Note the location of the wire springs.
3. Remove the two spring assemblies.
4. Lift belt assembly up and out of housing and remove belt.
5. Vacuum and clean housing of all loose toner.
6. Slide new belt on, return belt assembly to housing.
Figure 1
7. Replace springs on shaft, and hold cover up at an angle (spring rods fit into
grooves in housing).
8. Install the housing and secure with four screws.
9. Install corona grid and secure with two screws
Printer Compatibility:
ADVANCED TECH INTL 0880
APOLLO COMPUTER LP800
BURROUGHS AP 9206, AP 9208
DEC LN 03, 03 IC/P, 03 IMAGEPRINTER,
03 PLUS, RF-LN 03, RF-LN 03 TEMPEST
Figure 2
RF-LN 03S, RF-LN 03S TEMPEST
SCRIPTPRINTER
DIGITAL DESIGN CHECK PTR636 MICR
HONEYWELL MODEL 80, PRT 7550
PRU 7260, PRU 7261, PRU 7262
PRU 9960, PRU 9961, PRU 9962
LASERMASTER 4081
OASYS LASERPRO 810-R
PERSONAL COMP LASERIMAGE 2020
QUADRAM QUADLASER POSTSCRIPT, PLUS
RICOH LP 4080, 4080 R, 4081, 4081 E, 4081 R1
TI OMNILASER 2108
TROY 308 MICR
UNISYS AP 9208
WALLACE COMP SERV TI 2108
© 2001 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis Imaging
Products, Inc. may result in legal action. All registered trademarks are the property of their respective owners.
Oasis Imaging Products, Inc. Technical Support: (888) 627-6555