background
TEC® LB 1321/1323
Remanufacturing Instructions
Reference Information:
OEM PN: 392078
OEM Yield: 10,000 (5% coverage)
Recommended Tools:
Phillips screwdriver
Utility knife
Instructions:
Figure 1
1. Remove C Clip from left side of drum axle (Fig. 1).
2. Remove rod from unit (left side Fig. 2).
3. Remove drum: clean, inspect, replace if necessary.
4. Unfasten corona assembly and handle cover by unfastening two contacts and
two snap clips (Fig. 2).
Figure 2
5
.
Unfasten two snap clips from other side (Fig. 1).
6. Clean corona assembly with a cotton swab saturated in 99% IPA (Fig. 3).
7. Remove wiper blade (2 screws Fig. 4).
8. Clean, inspect, replace if necessary.
Figure 3
9. Use a utility knife to cut along seam and separate waste hopper (Fig. 1 & 2).
10. Remove top cover (Fig. 5).
11. Use compressed air or a vacuum to clean out excess toner.
12. Replace waste cover and glue down.
13. Replace wiper blade back and secure with two screws.
Figure 4
14. Replace corona assembly.
15. Install drum and slide rod back on. Be sure to lubricate the drum with pad-
ding powder.
16. Snap on C Clip.
Note: The Drum counter must be changed.
Figure 5
© 2001 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis Imaging
Products, Inc. may result in legal action. All registered trademarks are the property of their respective owners.