Fuji® Dex 740/760 OPC Unit
Reference Information:
Printer Compatibility:
OEM PN: UA930-861
Fuji Dex 720, 740, 760
OEM Yield: 19,000 (5% coverage)
Konica Fax 860L/ 865L
Recommended Tools:
Approximate Remanufacturing
Figure 1
Phillips head screwdriver
Time: 20 min.
Instructions:
1. Remove 2 screws from top (Fig. 1) and remove corona wire assembly.
2. Remove end cap by unhooking the two hidden clips. Remove two screws
(Fig. 2).
Figure 2
3. Remove hidden screw (Fig. 3). Turn auger assembly to the right (Fig. 4)
to expose the drum axle.
4. Clean all contacts and remove the axle.
5. Remove screw from remaining drum axle bushing (Fig. 5). First remove
bushing then remove OPC.
6. Clean and inspect the OPC. Replace if necessary.
Figure 3
7. With a Phillips screwdriver, remove the 2 screws from back panel.
8. Vacuum out any waste toner. Remove the 2 screws securing the wiper blade.
Clean and inspect the wiperblade. Replace if necessary.
9. Replace the wiperblade and back panel.
Figure 4
10. Replace the OPC and attach gear hub and axles.
11. Replace the waste auger and 3 screws. Attach cover plate.
12. Clean both corona wires. Attach top corona wire assembly and secure with
screws.
Figure 5
© 2001 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis Imaging
Products, Inc. may result in legal action. All registered trademarks are the property of their respective owners.