Brother® HL 1240 Toner Cartridge Remanufacturing Instructions...
1
1
1
Lexmark E210
Remanufacturing Instructions
Oasis Imaging Products, Inc. Technical Support: (888) 627-6555
Reference Information:
Materials Needed:
Oem part # 10SO150
Drum: EDR1105
Toner: E2TN1055
OEM Yield:
2,000 pages @ 5%
Approximate Reman Time: 15 minutes
Tools
Required:
#2 Philips Screwdriver, small flat head screwdriver, needle-nose pliers, end
clippers, vacuum, compressed air.
1. With end-clippers cut and remove the
small plastic wall surrounding the center
locking screw. Using the needle-nose
pliers remove the screw and replace it
with a #2 self-tapping screw before re-
assembly (Fig 1).
2. Remove the other four screw from the
top of the cartridge (Fig 2).
Fig. 1
Fig . 2
3. Push in locking tabs on the front of the
cartridge (Fig 3).
4. Carefully remove the top cover of
cartridge (Fig 4).
Fig. 3
Fig. 4
5. Vacuum out all remaining toner from
the toner hopper, sponge delivery roller
and cartridge interior (Fig 5).
6. Remove the three screws that hold the
gear side endplate in place, and then
remove the end plate (Fig 6).
Fig. 5
Fig. 6

New Hampshire
Illinois
Texas
California
Canada
Tennessee Europe
(603) 880-3991 (630) 928-1543 (972) 613-0200 (714) 237-1880 (905) 568-3422 888/757-0762 011-31-24-3882233
(888) 627-6555 (888) 658-4555 (888) 591-3555 (888) 656-9555 (800) 430-7886 Fx: (901) 366-9756 Fx: 011-31-24-3557373
Fx: (603) 598-4277 Fx: (630) 928-1542 Fx: (972) 613-9850 Fx: (714) 237-1889 Fx: (905) 568-3491
© 2003 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent of Oasis
Imaging Products, Inc. may result in legal action. All registered trademarks are the property of their respective owners.
Fig. 5
Fig.6
Fig. 7
7. End plate removal. Pcr will remain
in place untill other end cap is
removed (Fig 7).
8. Note Gear orientation in case any
of them fall off during the
remanufacturing process (Fig 8).
Fig .7
Fig . 8
9. Remove the three screws to release
end cap from the non-geared side of
the cartridge shell. (Fig 9).
10. Remove PCR from the cartridge.
Leave the drive gear on the PCR shaft
(Fig .10).
.
Fig . 9
Fig .10
11. Remove the two screws that hold the
foam PCR cleaner in place. CAUTION:
there is a thin piece of urethane that acts
as a wiperblade attached to the underside
of the cleaning bar, do not damage this
component when removing the cleaning
bar.
12. Remove the opc drum from the large
helical gear end.
Fig .9
Fig .10
Fig .11
Fig .12
Fig .13
Fig . 14
13.Clean the developer roller as well
as the sponge roller with compressed
air. It is not recommended to remove
the Dr. Bar assembly because of the
possibility of damaging the sealing
foam (Fig. 13). After reinstalling all
components in reverse order, fill
hopper with toner then replace top
cover.
14. Individual cartridge components
laid out ( Fig 14.)