LX Fuser Measurements

If you measure values in the indicated range on the left hand side of the fuser, the lamp is fine (240V fusers will read 3-4 times higher on the left hand side).



Models
HP IIP/IIIP, Apple PLW LS/NT/NTR (Check our cross reference guide for other brands)

Removal Instructions
To remove the fuser assembly, remove the five big brass screws holding the fuser in. To remove the fuser, you have to pull out on the side of the printer as you lift the fuser up. The way I do it is by putting my fingers underneath the ends of the fuser, and then pushing outwards on the sides with both thumbs while lifting.

If you don't have a meter, continuity can also be checked across the contacts on the left hand side of the fuser by using a digital tester.